Research & Development World

  • R&D World Home
  • Topics
    • Aerospace
    • Automotive
    • Biotech
    • Careers
    • Chemistry
    • Environment
    • Energy
    • Life Science
    • Material Science
    • R&D Management
    • Physics
  • Technology
    • 3D Printing
    • A.I./Robotics
    • Software
    • Battery Technology
    • Controlled Environments
      • Cleanrooms
      • Graphene
      • Lasers
      • Regulations/Standards
      • Sensors
    • Imaging
    • Nanotechnology
    • Scientific Computing
      • Big Data
      • HPC/Supercomputing
      • Informatics
      • Security
    • Semiconductors
  • R&D Market Pulse
  • R&D 100
    • Call for Nominations: The 2025 R&D 100 Awards
    • R&D 100 Awards Event
    • R&D 100 Submissions
    • Winner Archive
    • Explore the 2024 R&D 100 award winners and finalists
  • Resources
    • Research Reports
    • Digital Issues
    • R&D Index
    • Subscribe
    • Video
    • Webinars
  • Global Funding Forecast
  • Top Labs
  • Advertise
  • SUBSCRIBE

NIST and Intel Team Up for X-ray Technology

By R&D Editors | October 21, 2015

An example CDSAXS scattering pattern (left) shows the interference patterns created by the shape of the nanostructure, which ultimately yield a “best fit” shape model (top, right). The corresponding cross-sectional image (bottom), obtained with a transmission electron microscope, shows the nanostructure measured by NIST and Intel researchers. Image: R.J. Kline/NISTResearchers from the National Institute of Standards and Technology (NIST) and Intel have reported success using an X-ray scattering technique to accurately measure features on a silicon chip to within fractions of a nanometer, or about the width of a single silicon atom.

The achievement could make the experimental technology known as CDSAXS (critical-dimension small angle X-ray scattering) a top contender in the race to develop new in-line process control tools for measuring vanishingly small features on next-generation computer chips.

“The semiconductor industry is running out of measurement methods that work non-destructively on their ever-smaller next-generation nanostructures,” says NIST materials scientist R. Joseph Kline. “These are by far the smallest and most complex shaped nanostructures characterized by CDSAXS. The results show that CDSAXS has the resolution to meet next-generation metrology requirements.”

With the size of lines, trenches, holes and other features on silicon slices shrinking to single-digit nanometers, measurement tools long used to monitor chip production are approaching their limits. Factor in the growing complexity of chip design — such as building stack-like transistors instead of flat ones, a shift begun with Intel’s introduction of FinFET transistors in 2011 — and it’s easy to understand why semiconductor manufacturers are eager for improved measurement capabilities.

The NIST and Intel researchers used CDSAXS to measure dimensions on silicon wafers fabricated at Intel’s research facilities with a periodic array of asymmetric lines. The array was made by pitch quartering, a method that quadruples the number of interconnect lines in a space that normally would accommodate only one. The intricate arrays of lines were made using multiple patterning steps chip makers now must employ to create features beyond the capabilities of existing light-based printing equipment. Throughout, getting precise measurements is critical; misalignments during the sequential patterning process can result in systematic errors, or flaws, in a chip.

A flaw of particular concern — and a focus of the NIST-Intel study — is pitch error, variations in the distance from one line edge to the next.

“The semiconductor industry has not only decreased product dimensions, but we’ve also developed increasingly complex 3D structures. These structures are becoming very difficult to characterize non-destructively with conventional in-line SEM [scanning electron microscope],” says Scott List, principal engineer in Intel’s Components Research Group. “Early results of NIST’s state-of-the-art CDSAXS measurements of these nanometer-sized structures have provided very useful atomic scale resolution of their 3D profiles.”

In the custom-made sample scrutinized in the study, lines resembling shark fins were 12 nanometers wide. The space between lines varied ever so slightly — by less than 0.5 nanometer — from a pitch of 32 nanometers.

CDSAXS measurements of periodic pitch errors — deviations from 32 nanometers — were accurate to within 0.1 nanometer; and measurements of line shapes were accurate to about 0.2 nanometer.

Since 2000, NIST has been pioneering the application of small-angle X-ray scattering to meet the ever-more demanding measurement needs of the semiconductor industry, which, for decades, has been doubling the density of transistors on a chip about every two years in accordance with Moore’s Law. Today’s leading-edge integrated circuits squeeze several billion transistors on a slice of silicon smaller than a typical postage stamp.

Currently used dimensional metrology tools rely on visible and ultraviolet light with wavelengths much larger than the features being measured. The X-rays used in CDSAXS have a wavelength less than 0.1 nanometer, much smaller than the dimensions of features on future generations of computer chips. CDSAXS exploits the short wavelength of X-rays and their sensitivity to differing densities of electrons in the materials they strike.

The noncontact, non-destructive technique does not require any sample preparation, and it works with test structures already used by semiconductor makers. CDSAXS, however, does not yield the equivalent of an X-ray picture of, for example, a broken wrist. Rather, patterns of X-rays scattered by electrons in the nanostructure are captured by a detector, providing data to be crunched by computers to solve for the original shape.

The analyses compare the pattern of scattered X-rays to carefully developed shape models of arrays of nanostructured features on a surface. This data-fitting procedure may go through several million rounds before achieving a satisfactory match between simulated and measured patterns of electron densities.

Following other studies demonstrating the capabilities of CDSAXS for a host of nanoscale measurements, the NIST-Intel study on complex samples representative of next-generation semiconductor manufacturing shows that CDSAXS can deliver the desired dimensional resolution.

The results should provide further impetus for ongoing efforts to develop compact sources of X-rays with the intensity required for in-line CDSAXS in semiconductor manufacturing facilities. The NIST-Intel, proof-of-concept study was conducted at the Advanced Photon Source (APS) at Argonne National Laboratory, which measures 1,104 meters in circumference — more than 12 football fields around — and accommodates more than 60 experiments at one time. Previous CDSAXS studies were conducted at APS or similar experimental facilities, known as synchrotron light sources.

Release Date: October 20, 2015
Source: NIST http://www.nist.gov/mml/nist-and-intel-get-critical-dimensions-with-x-rays.cfm

Related Articles Read More >

TSMC’s N3P hits mass production, with N3X customer sampling slated for Q3–Q4 2025a
7 major R&D developments this week: Tariff uncertainty persists, Pfizer sells campus, Scania acquires Northvolt unit
While Trump tariffs spare phones/PCs, R&D could faces GPU cost pressures
Why IBM predicts quantum advantage within two years
rd newsletter
EXPAND YOUR KNOWLEDGE AND STAY CONNECTED
Get the latest info on technologies, trends, and strategies in Research & Development.
RD 25 Power Index

R&D World Digital Issues

Fall 2024 issue

Browse the most current issue of R&D World and back issues in an easy to use high quality format. Clip, share and download with the leading R&D magazine today.

Research & Development World
  • Subscribe to R&D World Magazine
  • Enews Sign Up
  • Contact Us
  • About Us
  • Drug Discovery & Development
  • Pharmaceutical Processing
  • Global Funding Forecast

Copyright © 2025 WTWH Media LLC. All Rights Reserved. The material on this site may not be reproduced, distributed, transmitted, cached or otherwise used, except with the prior written permission of WTWH Media
Privacy Policy | Advertising | About Us

Search R&D World

  • R&D World Home
  • Topics
    • Aerospace
    • Automotive
    • Biotech
    • Careers
    • Chemistry
    • Environment
    • Energy
    • Life Science
    • Material Science
    • R&D Management
    • Physics
  • Technology
    • 3D Printing
    • A.I./Robotics
    • Software
    • Battery Technology
    • Controlled Environments
      • Cleanrooms
      • Graphene
      • Lasers
      • Regulations/Standards
      • Sensors
    • Imaging
    • Nanotechnology
    • Scientific Computing
      • Big Data
      • HPC/Supercomputing
      • Informatics
      • Security
    • Semiconductors
  • R&D Market Pulse
  • R&D 100
    • Call for Nominations: The 2025 R&D 100 Awards
    • R&D 100 Awards Event
    • R&D 100 Submissions
    • Winner Archive
    • Explore the 2024 R&D 100 award winners and finalists
  • Resources
    • Research Reports
    • Digital Issues
    • R&D Index
    • Subscribe
    • Video
    • Webinars
  • Global Funding Forecast
  • Top Labs
  • Advertise
  • SUBSCRIBE